VZO Technical Data | ||
CONTOIL® Classic VZO 4...50 | ||
VZO 4 and 8 |
Volume display and remote transmission Volume display on roller counter Reed pulser for remote totalisation (option) Housing with thread connection / flange connection |
Type | VZO 4 Qmin0.5 |
VZO 4 | VZO 8 | VZO 15 | VZO 20 | VZO 25 | VZO 40 | VZO 50 | |
Nominal diameter, DN | mm | 4 | 4 | 8 | 15 | 20 | 25 | 40 | 50 |
Nominal Pressure, PN | bar | 25 | 16 with threaded ends ; 25 , 40 with flange | ||||||
Maximum temperature | °C | 60 | 130 , 180 | ||||||
Maximum flow rate Nominal flow rate Minimal flow rate |
l/h l/h l/h |
40 25 0.5 |
80 50 1 |
200 135 4 |
600 400 10 |
1,500 1,000 30 |
3,000 2,000 75 |
9,000 6,000 225 |
30,000 20,000 750 |
Max. permissable error | ± 1% of actual value | ||||||||
Weight with thread ends | approx. kg | 0.65 | 0.65 | 0.75 | 2.2 | 2.5 | 4.2 | 17.3 | - |
Weight with flanges PN 25 | approx.kg | 3.8 | 4.5 | 7.5 | 20.3 | 41.0 | |||
Weight with flanges PN 40 | approx.kg | 4.4 | 5.5 | 7.8 | 20.5 | 42.0 |